Mounting the LumiNode

Mounting the LumiNode

Depending on the model of the device there are different mounting options:

LumiNode 4

LumiNode 4 is a device that can be mounted in a truss as well as in a rack. Please read the following instructions to make sure the device is mounted and secured correctly.

Rack mount - LumiNode 4

In case you want to mount your LumiNode 4 in a standard 19-inch rack, you must attach the included mounting ears. Connect the longest ear (A) to the right-hand side of the device with 4 screws, re-used from the device. Attach the shorter ear (B) to the left-hand side again with the 4 screws.


Rack mount - two devices

In case you want to mount two LumiNode 4 devices or a LumiNode 4 and a LumiCore in a standard 19-inch rack you can mount the two devices together. A space saving way as the two devices will only consume a single row in your 19-inch rack.
First you attach the shortest mounting ears. Connect the shortest ear (C) to the left-hand side of the first device with 4 screws, re-used from the device. Attach the other shortest ear (D), delivered with the second device, to the right-hand side of the second device, again with 4 screws. Use a pair of mounting brackets (E) to connect the two devices in the middle on the frontside. Use a second pair of mounting brackets (E), delivered with the second device, to connect the devices at the rear. Each pair of brackets musts be mounted with 2 screws.


To combine a LumiNode 4 device with a Luminex half 19” device, style GigaCore 10, the mounting procedure differs a little.
The bolt (F), not included, replaces the couplers at the rear side of the device. Use the correct bold, M10x20 socket headcap screw, with a screw wire no longer than 20mm. You can order this part from Luminex (Part Number: R 90 01042).
Screw the bolt, through the LumiNode 4 back ear, into the side M10 insert and tighten it. The rest of the mounting procedure remains the same.





Truss Mount - LumiNode 4

To mount a LumiNode 4 in a truss, you must attach a M10 clamp (G) to the M10 insert (H). After that, you can mount the clamp to the truss bars. Please also secure the device by attaching a safety line directly to the truss bars as well (I).




LumiNode 2

LumiNode 2 is a device that can be mounted in a truss or on a flybar as well as on the wall. Please read the following instructions to make sure the device is mounted and secured correctly.

Truss Mount - LumiNode 2

To mount a LumiNode 2 in a truss, use the two plastic tie wraps that are included. Bring on each side a tie wrap through the holes of the device, around the truss bar and tighten it (J).  Please also secure the device by attaching a safety line directly to the truss bars (K).



Wall Mount - LumiNode 2

The LumiNode 2 can be mounted to a wall by using applicable screws and anchors. Make sure that the screw head diameter is between 8 – 10mm and the screw length is at least 40mm to make a strong wall connection.
Drill 4 holes, at the correct distance in both directions as indicated in the picture below.
Mount the device in such way that the Ethernet and DMX ports are facing sideways, and the chassis side is perpendicular to the ground.



    • Related Articles

    • LumiNode firmware upgrade

      In this document we will explain how to upgrade the firmware on the LumiNodes. There is only ONE firmware file for ALL the models which makes it easy to start with as there won't be any confusion about having the correct file. How to get the latest ...
    • LumiNode / LumiCore patch generator

      LumiNode / LumiCore Patch Generator The LumiNode range offers the option to import csv files to fill the patch in a process engine. Attached to this article you will find an example excel spreadsheet with some handy macros to quickly make patches ...
    • Luminode SNMP MIB Details

      The Luminode range of products has SNMP capabilities. Here is a list of all the OID enabled in the MIB : System information .1.3.6.1.2.1.1.1 : system description .1.3.6.1.2.1.1.2 : object ID .1.3.6.1.2.1.1.3 : Uptime .1.3.6.1.2.1.1.5 : System name ...
    • LumiNode/LumiCore control channel values

      In the LumiNode/LumiCore there are different functions where a control channel can be assigned. All values are in the range 0 - 255. These are the control channel values for each of the available options: General: 0 - 7: Do Nothing Switch: 8 - 15: ...
    • LumiNode Advanced Networking

      In this article we will look at how to configure the network and advanced network options of the LumiNode. Firmware 2.3.0 or higher is required for these features. The interface has been redesigned in firmware 2.5.0. Note: It is not recommended to ...